Low Voltage Electric Project

Low Voltage Electrical Projects

New, expanded or existing facilities modified, that distribute electrical energy to receivers or generators for their own use with supply voltages equal to or less than 1000V in alternating current, or 1500V in direct current, must be defined for their legalization through technical documentation (project or technical report) according to the characteristics of said installation, and must be drawn up by a competent technician. The following facilities are the object of the low voltage electrical installation project: Industries with a planned power of more than 20kW. Premises that are humid, dusty or at risk of corrosion, as well as pump installations for extraction or elevation of water, industrial or not, with planned power greater than 10kW. Wet premises, generators, converters and insulated conductors for heating, excluding those in homes, with a planned power greater than 10kW. Temporary, for feeding construction site machinery, and in premises or open locations with power Expected power exceeding 50kW. Buildings destined mainly for homes, commercial premises and offices that are not considered to be of public concurrence with power expected by the General Protection Fund greater than 100kW. Single-family homes with a planned power greater than 50kW. Garages that require forced ventilation whatever whatever your occupation.Garages that have ventilation natural action of more than 5 parking spaces Public spaces, among which are those for entertainment and recreational activities, and those for meeting and work Low voltage lines with common high voltage supports, lifting and transport machines , installations that use special voltages, non-low-voltage luminous signs, electric fences, and overhead and underground distribution networks, with no power limit. Outdoor lighting installations with an expected power greater than 5kW. They must also be subject to compliance with RD.1890 / 2008 on energy efficiency of outdoor lighting installations Premises with risk of fire and explosion, except garages, without power limits Operating rooms and intervention rooms without power limits Swimming pools and fountains Expected power greater than 5kW. Those corresponding to the infrastructures for recharging electric vehicles with power greater than 50 kW. Recharging facilities located abroad. Power greater than 10 kW. All installations that include recharging stations planned for charging mode 4. All those not covered in the previous sections will be subject to a technical design report. Ariva Ingenieros designs these low voltage electrical installations, and carries out the pertinent technical documentation.

Contact us

More information about Privacy and Cookies Policy

Share by: